Technical Specifications at a Glance

Comprehensive technical details for the Socomec RF SYSTEM wireless communication modules

Parameter
Specification
Communication Frequency
902-928 MHz
Radio Power
25 dBm
Encryption
128 Bit AES
System Range
5 miles outdoor / 1000 ft indoor
Power Consumption
3 VA
Operating Temperature
-20°C to +60°C (-4°F to +140°F)
RF END-Node Power Supply
4.8-28 VDC
RF HUB-Node Power Supply
5.0 VDC
Dimensions
3.54 x 2.4 x 0.92 inches
Country of Origin
🇺🇸 USA

Engineered for Industrial Excellence

Advanced wireless communication technology designed to streamline industrial automation and monitoring systems

Wireless Installation

Eliminates the need for expensive Ethernet LAN infrastructure and Modbus RS485 wiring runs, saving significant installation time and reducing overall system costs while maintaining reliable communication.

Secure Communication

128-bit AES encryption ensures data confidentiality and security for critical industrial applications, protecting sensitive operational data from unauthorized access and maintaining system integrity.

Easy Commissioning

Simple PC application (RF-View) via USB connection provides visual signal strength monitoring, making setup and configuration straightforward for technicians and reducing deployment time significantly.

Industrial Grade Design

Rugged aluminum body construction with extendable multi-position antenna and easy-access LED status lights ensures reliable operation in harsh industrial environments and simplifies troubleshooting procedures.

Extended Range

Impressive 5-mile outdoor line of sight range and 1000-foot indoor commercial range provides flexibility for large facility deployments and campus-wide networking applications without signal degradation.

Self-Powered Operation

RF END-Node mounts directly on DIRIS MCM meters and operates with minimal power consumption of 3 VA, eliminating the need for separate power supplies and reducing installation complexity.

Frequently Asked Questions

What is the communication range of the RF SYSTEM?
The RF SYSTEM provides up to 5 miles outdoor line of sight range and 1000 feet indoor commercial range, making it suitable for large facility and campus deployments with reliable wireless communication.
How many RF END-Nodes can connect to one RF HUB-Node?
Each RF HUB-Node can support up to 8 RF END-Nodes, providing flexible network topology for medium to large-scale monitoring systems with centralized data collection and management.
What security features does the RF SYSTEM include?
The system includes 128-bit AES encryption for data confidentiality, ensuring secure wireless communication and protecting sensitive operational data from unauthorized access in industrial environments.
Is special software required for configuration and monitoring?
Yes, the RF-View PC application provides easy commissioning via USB connection with visual signal strength monitoring and test utilities for both on-site and off-site data monitoring and system management.
What power requirements does the RF SYSTEM have?
The RF END-Node requires 4.8-28 VDC power supply while the RF HUB-Node requires 5.0 VDC. Both units consume only 3 VA, making them energy-efficient for continuous operation.

Versatile Applications Across Industrial Sectors

Designed to meet diverse communication needs in modern industrial and facility management environments

Sub-metering applications for energy monitoring in commercial buildings and industrial facilities#16:9

Sub-Metering Applications

Replaces traditional Ethernet LAN infrastructure for energy monitoring and data collection in commercial and industrial facilities

Facility and campus environment networking with wireless communication systems#16:9

Facility & Campus Networking

Ideal for large facility and campus environments requiring reliable wireless communication across multiple buildings and locations

EMS BMS system integration for building automation and energy management#16:9

EMS/BMS Integration

Seamlessly integrates with Energy Management Systems and Building Management Systems for comprehensive facility automation

DIRIS MCM meter wireless communication for Modbus device networking#16:9

DIRIS MCM Meter Communication

Enables wireless communication of Modbus devices when used with DIRIS MCM meters for distributed monitoring systems

What Our Industrial Partners Say

Real experiences from engineers and maintenance professionals who rely on our wireless communication solutions

Eliminated Complex Wiring Issues

ValuAdd's technical expertise with the RF SYSTEM saved us weeks of troubleshooting on our wireless communication setup. Their deep product knowledge made all the difference in our facility upgrade.

Perfect for System Integration

The RF SYSTEM's reliability and ValuAdd's component selection support have made them our go-to partner for wireless communication projects. Truly knowledgeable representatives.

Outstanding Technical Support

The local support and territory-based service from ValuAdd is exceptional. They understand our industrial communication challenges and provide solutions that work perfectly.

Streamlined Installation Process

The RF SYSTEM eliminated our need for extensive cable runs across our facility. ValuAdd's guidance on wireless setup saved us both time and installation costs significantly.

Reliable Secure Communication

The 128-bit encryption and robust design give us confidence in our critical data communications. ValuAdd's expertise helped us select the perfect configuration for our needs.

Perfect for Automation Projects

The seamless EMS integration and extensive range capabilities make this system ideal for our automation projects. ValuAdd's ongoing support has been invaluable for our implementations.

Complete Communication Solutions

Explore our comprehensive range of DIRIS communication modules and accessories for complete system integration

DIRIS Digiware C-31

Compact RS485 system interface with 24 VDC Safety Extra-Low Voltage power supply for centralized data collection without local display requirements.

DIRIS Digiware RJ45 bus termination

Essential RJ45 terminating resistor component that must be placed on the last module of the Digiware bus for proper system operation.

Need a Custom Wireless Solution?

Our technical experts can help design the perfect RF SYSTEM configuration for your facility requirements

Ready to Upgrade Your Communication System?

Connect with our industrial electrical experts to discuss your wireless communication needs and get personalized system recommendations

For immediate assistance, call us at +1 (555) 123-4567 or email us at info@valuadd.com

Request Technical Consultation

For immediate assistance, call us at +1 (555) 123-4567 or email us at info@valuadd.com